Flame-CHEM
User Interchangeable Slits
Best for users who wish to vary resolution and throughput during measurements, or switch from absorbance to fluorescence in minutes.
Example Application: Life science and other labs using a variety of biological samples.
Indicator LED
Convenient visual reference for spectrometer operation and status.
Example Application: Teaching and general lab use.
Thermal Stability
Best for applications that require repeatable results in industrial and other environments with varying temperatures and conditions.
Example Application: LED binning and light metrology, process monitoring.
Reduced Unit to Unit Variation
Best for OEM applications such as uncalibrated sensitivity and other measurement needs where users benefit from low variance
Example Application: OEM manufacturers of analytical instrumentation
Configurability
Best for optimizing your spectrometer for application-specific requirements; adjusting range, throughput and resolution and adding features such as filters as required
Example Application: Laser characterization, low signal fluorescence and optimizing for specific absorbance bands
Plug & Play Operation
Best for users that want the convenience of simple, fast operation via the microUSB connection; enables users to take the measurement to the sample
Example Application: Remote sensing measurements in the field, including air and water quality monitoring and solar irradiance
Ease of Integration
Best for OEMs and developers who need to integrate a spectrometer as part of a system via microUSB or RS-232
Example Application: Engineering labs, developers, OEM manufacturers; works with LabVIEW and other design platforms
UV-VIS
Specifications
Detector:
Detector: linear silicon CCD array
Pixels: 2048
Detector Collection Lens: No
Electronics
A/D Resolution: 16 bit
A/D Connectors: USB, high density 40 pin JAE DD4 connector
Inputs/Outputs: 8 x user programmable GPIOs
Trigger Modes: 4 modes
Illumination Source: Tungsten halogen with a violet LED (~390-1000 nm)
Power Consumption: 250 mA @ 5 VDC
Spectroscopy:
Integration Time: 1ms – 65s
Optical Resolution: 1.33 nm FWHM (typical)
Wave Length Range: 350nm – 1μm
Dark Noise: 50 RMS counts
Dynamic Range: 1300:1 for a single acquisition
Input Fiber Connector: SMA 905
Signal to Noise Ratio: 250:1 (full signal)
Stray light: <0.10% at 435 nm
VIS-NIR
Specifications
Detector:
Detector: linear silicon CCD array
Pixels: 2048
Detector Collection Lens: No
Electronics
A/D Resolution: 16 bit
A/D Connectors: USB, high density 40 pin JAE DD4 connector
Inputs/Outputs: 8 x user programmable GPIOs
Trigger Modes: 4 modes
Illumination Source: Tungsten halogen with a violet LED (~390-1000 nm)
Power Consumption: 250 mA @ 5 VDC
Spectroscopy:
Integration Time: 1ms – 65s
Optical Resolution: 1.33 nm FWHM (typical)
Wave Length Range: 350nm – 1μm
Dark Noise: 50 RMS counts
Dynamic Range: 1300:1 for a single acquisition
Input Fiber Connector: SMA 905
Signal to Noise Ratio: 250:1 (full signal)
Stray light: <0.10% at 435 nm