Integrating Sphere-Reflectance

$0.00

  • *Diameter

    • $
    • $
    • $

    *Application

    • $
    • $

    Detailed Product Description:

    Integrating Sphere, 30 mm, for irradiance

    Detailed Product Description:

    Integrating Sphere, 50 mm, for irradiance

    Detailed Product Description:

    Integrating Sphere, 80 mm, for irradiance

    Detailed Product Description:

    Integrating Sphere, 30 mm, for reflection

    Detailed Product Description:

    Integrating Sphere, 50 mm, for reflection

    Detailed Product Description:

    Integrating Sphere, 80 mm, for reflection

ISP-R series fiber optic integrating spheres couple to Ocean Optics spectrometers to measure the total integrated reflectance of surfaces placed against the sphere’s sample port. ISP-R integrating spheres are well-suited for measurement of opaque or highly directional samples. The spheres are available in 6 mm and 8 mm sample port diameters and gloss-trap options are available that allow you to measure the specular component of the total integrated reflection.

  • Sphere Material – PTFE
  • Wavelength Range – 200-2500 nm (material)
  • Sample Port Diameter – 8 mm
  • Sphere diameter – 80 mm

ISP-I Integrating Spheres connect to our spectrometers and optical fibers to measure the spectral output of LEDs, lasers and other light sources. Each sphere consists of a PTFE-based, sintered diffusing material that provides a Lambertian surface (with >98% reflectivity in the visible) for irradiance measurements.

  • Sphere material – PTFE
  • Wavelength range – 200-2500 nm (material)
  • Sample port diameter – 8 mm
  • Sphere diameter – 80 mm

ISP-30-6-R

Specifications


Engineering

Gloss Trap: No
Sample Port Diameter: 6 mm
Spectral Range: 200-2500 nm
Sphere Coating: PTFE
Sphere Diameter: 30 mm
Connector: SMA 905
Dimensions: 59 mm diameter x 58 mm height
PTFE Reflectivity: >98% (400-1500 nm)>95% (250-2500 nm)
Weight: 330 g

ISP-50-8-R

Specifications


Engineering

Gloss Trap: No
Sample Port Diameter: 8 mm
Spectral Range: 200-2500 nm
Sphere Coating: PTFE
Sphere Diameter: 50 mm
Connector: SMA 905
Dimensions: 80 mm diameter x 78 mm height
PTFE Reflectivity: >98% (400-1500 nm)>95% (250-2500 nm)
Weight: 730 g

ISP-80-8-R

Specifications


Engineering

Gloss Trap: No
Sample Port Diameter: 8 mm
Spectral Range: 200-2500 nm
Sphere Coating: PTFE
Sphere Diameter: 80 mm
Connector: SMA 905
Dimensions: 107 mm diameter x 117 mm height
PTFE Reflectivity: >98% (400-1500 nm)>95% (250-2500 nm)
Weight: 1650 g

ISP-30-6-I

Specifications


Engineering

Gloss Trap: No
Sample Port Diameter: 6 mm
Spectral Range: 200-2500 nm
Sphere Coating: PTFE
Sphere Diameter: 30 mm
Connector: SMA 905
Dimensions: 107 mm diameter x 117 mm height
LED Adapter: No
PTFE Reflectivity: >98% (400-1500 nm); >95% (250-2500 nm)
Weight: 330 g

ISP-50-8-I

Specifications


Engineering

Sample Port Diameter: 8 mm
Spectral Range: 200-2500 nm
Sphere Coating: PTFE
Sphere Diameter: 50 mm
Dimensions: 80 mm diameter, 78 mm height
LED Adapter: For 3 mm, 5 mm or 8 mm LEDs
PTFE Reflectivity: >98% (400-1500 nm); >95% (250-2500 nm)
Weight: 730 g

ISP-80-8-I

Specifications


Engineering

Sample Port Diameter: 8 mm
Spectral Range: 200-2500 nm
Sphere Coating: PTFE
Sphere Diameter: 80 mm
Dimensions: 107 mm diameter, 117 mm height
LED Adapter: No
PTFE Reflectivity: >98% (400-1500 nm); >95% (250-2500 nm)
Weight: 1650 g