QE-Pro Raman Series

Categories: ,

$0.00

  • *Wavelength Range

    • $
    • $
    • $

    Detailed Product Description:

    Preconfigured QEPRO for 532nm Raman

    Detailed Product Description:

    QEPRO-RAMAN-638 spectrometer Assembly

    Detailed Product Description:

    QEPRO, #H43, DET-QE, INTSMA-050-F3,

  • Portable – small footprint, light weight, fiber optic-based spectrometer
  • Sensitive – 3X sensitivity improvement and wider spectral range than earlier QE Pro-Raman
  • Powerful – signal-to-noise ratio of >1000:1 (single acquisition)
  • Raman shift – 150-3000 cm-1 (w/standard Raman probe) and 0-3000 cm-1 (spectrometer)
  • Stable – cooled detector allows low light detection and extremely long integration times

QE Pro-Raman+ Product Sheet

Raman+

Specifications


Communications:

Wired: USB 2.0, 480 Mbps (USB 1.1 compatible); RS-232 (5-wire)


Detector:

Entrance slit: 50 µm
Quantum Efficiency 90% (peak)
Pixels: 1024


Electronics:

Power Requirement: Supply voltage: 4.5 – 5.5 V
Strobe Functions: Continuous and single strobe


Enviromental:

Humidity: ≤ 90% noncondensing
Operating Temperature: 0 °C – 50 °C


Physical:

Dimensions: 182 mm (7.17 in.) x 110 mm (4.33 in.) x 47 mm (1.85 in.)
Weight: 1.15 kg (2.6 lbs.); power supply: 0.45 kg (1 lb.)


Spectroscopy:

Integration Time: 8ms – 3600s
Optical Resolution: 0.72 nm FWHM (typical)
Raman Shift:0cm(-1) – 3000cm(-1)
Dynamic Range:~85,000:1
Input Fiber Connector:SMA 905
Onboard Memory:15,000 spectra
Signal to Noise Ratio:1000:1 (single acquisition)

Raman-532

Specifications


Communications:

Wired: USB 2.0, 480 Mbps (USB 1.1 compatible); RS-232 (5-wire)


Detector:

Detector: Back-thinned, TE Cooled, 1044 x 64 element CCD array
Entrance slit: 25 µm
Grating: GRATING_#H6
Quantum Efficiency 90% (peak)


Electronics:

Power Requirement: Supply voltage: 4.5 – 5.5 V
Strobe Functions: Continuous and single strobe


Enviromental:

Humidity: ≤ 90% noncondensing
Operating Temperature: 0 °C – 50 °C


Dimensions:

Dimensions: 182 mm (7.17 in.) x 110 mm (4.33 in.) x 47 mm (1.85 in.)
Weight: 1.15 kg (2.6 lbs.); power supply: 0.45 kg (1 lb.)


Spectroscopy:

Integration Time: 8ms – 3600s
Optical Resolution: 0.42 nm FWHM (typical)
Raman Shift:150cm(-1) – 4000cm(-1)
Dynamic Range: ~85,000:1
Input Fiber Connector: SMA 905
Onboard Memory: 15,000 spectra
Signal to Noise Ratio: 1000:1 (single acquisition)

Raman-638

Specifications


Communications:

Wired: USB 2.0, 480 Mbps (USB 1.1 compatible); RS-232 (5-wire)


Detector:

Entrance slit: 25 µm
Grating: GRATING_#H6
Quantum Efficiency: 90% (peak)


Electronics:

Power Requirement: Supply voltage: 4.5 – 5.5 V
Strobe Functions: Continuous and single strobe


Enviromental:

Humidity: ≤ 90% noncondensing
Operating Temperature: 0 °C – 50 °C


Dimensions:

Dimensions: 182 mm (7.17 in.) x 110 mm (4.33 in.) x 47 mm (1.85 in.)
Weight: 1.15 kg (2.6 lbs.); power supply: 0.45 kg (1 lb.)


Spectroscopy:

Integration Time: 8ms – 3600s
Optical Resolution: 0.42 nm FWHM (typical)
Raman Shift: 150cm(-1) – 3158cm(-1)
Dynamic Range:~85,000:1
Input Fiber Connector:SMA 905
Onboard Memory:15,000 spectra
Signal to Noise Ratio:1000:1 (single acquisition)